BOILER CHARACTERISTICS
- The nominal productivity of saturated steam is 10 tons / hour
- The minimum productivity of saturated steam 1.4 tons / hour
- Nominal heat productivity 6.53 MW
- The nominal efficiency of 94%
- Estimated maximum vapor pressure (Mego Pascal) 1.3 M pass
- Working pressure pressure 2.47 M pass
- Working nominal steam pressure at the exit from the boiler 1.1 M pass
- Working nominal steam temperature at the exit from the boiler 180 degrees
- The calculated water temperature at the inlet of the boiler is 103 degrees
- The water volume of the boiler 11.80 cubic meters
- A pair of boiler volume 4.60 cubic meters
- Thermal pressure of the burning chamber 1.17 MW / m3
- Resistance of a gas boiler with an economizer of 12.5 m bar
- Flue gas temperature with economizer 140 degrees
- Loss of downtime 25 kW
- Flue gas losses 5.1%
- Thermal power of the burner from 1.0 to 10.6 MW
- Guaranteed capacity for harmful substances inNatural Gas: Carbon Monoxide. mg / nm cube greater than 80Nitric oxide NOx. mg / nm cube greater than 240
- Heating natural gas 9.3 Qp.kBt. hour / m cube
- The estimated use of natural gas is 745 cubic meters per hour.
- Transport weight of the boiler is 24 tons
- The mass of the boiler with water40.5 tons
Boilers are running and video is available on request.
Product Description
BOILER CHARACTERISTICS
- The nominal productivity of saturated steam is 10 tons / hour
- The minimum productivity of saturated steam 1.4 tons / hour
- Nominal heat productivity 6.53 MW
- The nominal efficiency of 94%
- Estimated maximum vapor pressure (Mego Pascal) 1.3 M pass
- Working pressure pressure 2.47 M pass
- Working nominal steam pressure at the exit from the boiler 1.1 M pass
- Working nominal steam temperature at the exit from the boiler 180 degrees
- The calculated water temperature at the inlet of the boiler is 103 degrees
- The water volume of the boiler 11.80 cubic meters
- A pair of boiler volume 4.60 cubic meters
- Thermal pressure of the burning chamber 1.17 MW / m3
- Resistance of a gas boiler with an economizer of 12.5 m bar
- Flue gas temperature with economizer 140 degrees
- Loss of downtime 25 kW
- Flue gas losses 5.1%
- Thermal power of the burner from 1.0 to 10.6 MW
- Guaranteed capacity for harmful substances inNatural Gas: Carbon Monoxide. mg / nm cube greater than 80Nitric oxide NOx. mg / nm cube greater than 240
- Heating natural gas 9.3 Qp.kBt. hour / m cube
- The estimated use of natural gas is 745 cubic meters per hour.
- Transport weight of the boiler is 24 tons
- The mass of the boiler with water40.5 tons
Boilers are running and video is available on request.