Product Description
Diesel Power Plant MAN 57.9 MW / 50 Hz with 3 x 18V48/60 TS Diesel Generators – year 2014
This diesel power plant consists of three identical 19.3 MW MAN 18V48/60 TS diesel generating units with auxiliaries. The engines are 500 rpm turbo charged with intercooling and they are installed on base frame forming a wet oil sump for engines. Diesel generators have been operated only approx. 5000 hours since new. Alternators are ABB made synchronous generators which are air-cooled, and they have their own lubrication oil system installed on concrete foundation and connected to the engines with flexible couplings. Engines are cooled with two separate cooling circuits connected to radiator cooling system. The control system is MAN SaCoS One. 11 kV breakers are Siemens SF6 type. The plant is still installed and fully operational and in good technical condition.
Main technical data
Manufacturer MAN Augsburg, Germany
Manufacturing year 2014
Plant capacity 57.9 MWe / 11 kV / 50 Hz
Total operating hours Approx 5000
Number of generating sets 3 pcs
Engine type MAN 18V48/60 TS
Engine speed 500 rpm
Electric power capacity 19305 kW Capacity (Continuous)
Fuel HSD (Diesel) consumption Original 182 g/kWhe +/- 5% (NCV 42700 kJ/kg)
Lube oil consumption Original 9.9 kg/hour, tolerance +20%
Alternator type ABB AMG 1600 Air-cooled
Alternator Capacity 24132 kVA
Voltage 11000V / 50 Hz
Product Description
Diesel Power Plant MAN 57.9 MW / 50 Hz with 3 x 18V48/60 TS Diesel Generators – year 2014
This diesel power plant consists of three identical 19.3 MW MAN 18V48/60 TS diesel generating units with auxiliaries. The engines are 500 rpm turbo charged with intercooling and they are installed on base frame forming a wet oil sump for engines. Diesel generators have been operated only approx. 5000 hours since new. Alternators are ABB made synchronous generators which are air-cooled, and they have their own lubrication oil system installed on concrete foundation and connected to the engines with flexible couplings. Engines are cooled with two separate cooling circuits connected to radiator cooling system. The control system is MAN SaCoS One. 11 kV breakers are Siemens SF6 type. The plant is still installed and fully operational and in good technical condition.
Main technical data
Manufacturer MAN Augsburg, Germany
Manufacturing year 2014
Plant capacity 57.9 MWe / 11 kV / 50 Hz
Total operating hours Approx 5000
Number of generating sets 3 pcs
Engine type MAN 18V48/60 TS
Engine speed 500 rpm
Electric power capacity 19305 kW Capacity (Continuous)
Fuel HSD (Diesel) consumption Original 182 g/kWhe +/- 5% (NCV 42700 kJ/kg)
Lube oil consumption Original 9.9 kg/hour, tolerance +20%
Alternator type ABB AMG 1600 Air-cooled
Alternator Capacity 24132 kVA
Voltage 11000V / 50 Hz